Re: Base address of servo to go board.




Hi Juan

I'm afraid not - The base address for the Kaluga/Camtronics DRO board is hard 
coded into EMC at present. You are stuck with 0x200 unless you recompile EMC.

Regards, Paul.


On Saturday 18 May 2002 00:25, Webstercnc-at-aol.com wrote:
> Hi Everyone,
>
> I want to use encoders with my steppers and I
> have a Camtronics Dro board.  In the generic.ini
> file at the [EMCMOT] section. There is an entry
> that says; Base address of servo to go board
>               STG_BASE_ADDRESS =      0X200
>               ;   STG_BASE_ADDRESS=   0X300
>
> Is this where I would put my DRO board address (544D)?
> If yes, Would this be correct if I modify my first address
> to read STG_BASE_ADDRESS       =       0X544D      ?
>
> Thanks,
>
> Juan



Date Index | Thread Index | Back to archive index | Back to Mailing List Page