Re: Fwd: pulse train
Hi Scot
Running a few tests with the latest CVS sources on the Athlon 1800, achieved
around 60KHz - 12500 steps per inch at 300 ipm. With a little bit more
tuning, I'd imagine this could go higher. At these frequencies, interrupt
latencies have a significant effect on the stability of the output - The read
/write timings of the parallel port may also limit the theoretical maximum
frequency.
Ultimately, it will be the stepper motors and drive electronics that will
determine the maximum usable frequency.
Regards, Paul.
On Monday 16 Dec 2002 12:11 am, Paul wrote:
> An Athlon 1800
> ran at ~7uSec (71500Hz pulse rate), but this left precious little time to
> do anything else.