Hi list

Thanx ray for your help, Ray. Now I am looking closer at tkio.tcl

I believe from reading the manual that this file can be modified to create a
plc(wrapper) for a machine.

Have done more testing and I think now that tkio can see 0x378 but it can
not see 0x278 because there is no code in tkio.tcl to change $PARPORT_IO
ADDRESS

Am I on the right track?

I also suspect that I can modify  "proc spindleControl" to facilitate the
following S-codes:

S01         | 40        | 70         |     X   |          |     X   |
|   X    |          |           |     X   |          |
S02         | 50        | 90         |     X   |          |     X   |     X
|         |          |           |     X   |          |
S03         | 60        | 110       |     X   |          |     X   |
|         |          |      X   |          |     X   |
S04         | 80        | 140       |     X   |          |     X   |
|         |     X   |           |          |     X    |
S05         | 100      | 180       |     X   |    X     |         |
|   X    |           |          |     X    |          |
S06         | 125      | 230       |     X   |    X     |         |     X
|         |           |          |     X    |          |
S07         | 150      | 275       |    X    |    X     |         |
|         |           |     X   |           |    X    |
S08         | 195      | 355       |    X    |    X     |         |
|         |     X    |          |           |          |
S09         | 265      | 470       |          |          |    X    |
|   X    |           |          |    X     |          |
S10         | 335      | 610       |          |          |    X    |     X
|         |           |          |    X     |          |
S11         | 400      | 730       |          |          |    X    |
|         |           |    X    |           |    X    |
S12         | 510      | 925       |          |          |    X    |
|         |     X    |          |           |    X    |
S13         | 635      | 1150     |          |    X     |         |
|    X    |          |          |     X     |         |
S14         | 820      | 1490     |          |    X     |         |     X
|         |          |          |     X     |         |
S15         | 980      | 1780     |          |    X     |         |
|          |          |    X    |           |    X    |
S16         | 1250    | 2250     |          |    X     |         |
|          |    X    |           |           |    X    |

the "X"'s represent solenoid status of a set of nine hydrualic valves.

I suspect that I would have to replace "proc spindleIncrease" and "proc
spindleDecrease" with a set of something like "proc spindle_is_S11" etc etc


Can anyone tell me if I am on the right track here?

Finally, if someone was clever enough to make a menu-driven tkio-wrapper
building program, wouldn't that be BUTE!?.

These are just newbie thoughts by the kero heater up the back shed ........

cheers

Peter Barrett