Re: Remote GUI




Hi Will

The IP addresses for the two machines are

B6 192.168.0.6 - Running the realtime motion control
B2 192.168.0.2 - Hopefully the remote GUI.

The attached log was from B2 when it was trying to connect to B6 running EMC.

After looking again at the error logs, I have finally got it to run, Yipee.
Now I just need to add my notes to the Handbook and then test the tkemc.exe.


Regards, Paul.



On Tuesday 19 March 2002 21:24, Will Shackleford wrote:
> On Tue, 2002-03-19 at 16:02, Paul wrote:
>
> The server should never be REMOTE.
>
> find the line
>
>  P emcsvr        emcError        REMOTE B6       R       1       1.0     0
>       2
>
> in emc.nml and change the REMOTE to LOCAL.
>
> Run the server on the same system as the TASK, IO and MOTION code not on
> the system with just the remote gui.
>
> -- Will



Date Index | Thread Index | Back to archive index | Back to Mailing List Page