Hi Fred Setting up an STG II card and doing some testing, I have noticed a quirk (bug ?). During a homing cycle, if a limit switch is hit, the amps are disabled but the DAC output remains active. During any other move, if the home switches are tripped, both the amp enables and the DAC outputs are reset. Regards, Paul.