Lube



 Is it normal for a cnc controller to shutdown the mist colant, flood
coolant, and lube, when toggled from auto or mdi modes, to manual mode?

If the operator doesn't notice he would be running the machine without the
lube timer enabled.

For manual mode, EMC_TASK_SET_MODE = 1.
When I toggle from auto or mdi back to manual, EMC_TASK_PLAN_SYNCH = 0.

Does this have to reset the lube to off?  Would it not be safer to have the
lube on as long as the machine is on (ie: EMC_TASK_SET_STATE = 4), unless
the operator turns it off?

Kurtis