RE: EMC error message?




Tim

I set up 15-Mar today and get the same message.  Looks like NIST set up
some more detailed messaging in this release.  If your axis switch polarity
is wrong it will tell you using the standard out. I think that the message
you're getting just means that one part has loaded and is looking for
another before the other is ready.

If you set period high enough you will get several before tkemc comes up.
They don't seem to affect running at all.  In fact I used a combination of
these messages and mouse pointer stutter to tell me where to set period.
Wound up with 0.000025 on my pr300 no-name box.

Ray
 

At 09:36 PM 3/19/2000 -0500, you wrote:
>
>Hate to be replying to my own message, but I have set up the 15-mar-2000
>build on my real system and set the period to 0.0000083 (1/2 of what the
>.txt file says is equivalent to 20 as I was using a period of 10 for the
>compiled parameter). I am now getting the same error as below one or 2 times
>and then the tkemc interface comes up and everything seems to work fine.
>Still wondering about the significance of this message and how to eliminate
>it.
>
>Tim
>[Denver, CO]
>





Date Index | Thread Index | Back to archive index | Back to Mailing List Page